Reference Junction Units- WHY?

1. Thermocouple output is dependent of temperature of hot junction and temperature of cold junction.
2. The Cold junction temperature needs to be known to get the hot junction temperature.
3. To reduce the uncertainity of cold junction measurement Reference junction boxes are used.
4. A reference junction box terminates the thermocouple cold end at a known and constant temperature. This can be 0 deg or 60 Deg C, as per user requirement.
5. The EMF of the reference junction is fixed and is added on to the output of the thermocouple.

Tempsens Is offering models calREF 0 (Peltier based, used for Maintaining 0 deg C) & calRef 60 (Resistance heating based generally for maintaining 60 deg C).
 
 
CalREF 0 - Reference Unit   CalREF-60 - Reference Unit    
   
       
Key Features:   Key Features:  
       
  • 0 deg C Thermoelectric reference unit
  • Eliminates Old Fashioned "Ice Bath"
  • Versatile use in industries,
    Laboratories, Instrument Shop
  • NABL Traceable Calibration Available
 
  • 60 deg C Thermoelectric reference unit
  • Versatile use in factory, Laboratory,
    Instrument Shop
  • Rugged Outer case for safe Portability
  • NABL Traceable Calibration Available
 
       
Read More   Read More  
       
 